Version 7.1

BUILD 197        2015/06/10

WARNING:

 This installation requires a change to the existing database.

Connections

SERIAL

  • Added logic to provide information to the Queue Viewer.
  • Corrected some of the diagnostic counter items that weren’t updated correctly.

TCPIP

  • Added logic to provide information to the Queue Viewer.
  • Corrected some of the diagnostic counter items that weren’t updated correctly.

TCPLISTEN

  • Added logic to provide information to the Queue Viewer.
  • Corrected some of the diagnostic counter items that weren’t updated correctly.
  • ‘Connected’ log message is now optional.

TCPPOOL

  • Added logic to provide information to the Queue Viewer.
  • Corrected some of the diagnostic counter items that weren’t updated correctly.
  • New command to set modem health to good.

UDPBSAP

  • Initial release – New port type to improve Ethernet BSAP polling performance.

Protocols

ALL PROTOCOLS

  • Added SecondsSinceComplete and MinutesSinceComplete standard items.
  • Added support for per-interval demand polling.
  • Fix to prevent delayed response to client when an OPC write fails.

BSAP

  • Fix to correctly process GC Write response from Teleflow.
  • Fix for sequence numbers (assigned only when message is sent to the device).
  • Fix for sequence numbers (assigned from single source value).
  • Fix to properly handle receive messages from ‘other’ devices.
  • Addition to handle multi-message responses.
  • Added new properties for sub-packet settings.

CONTROLLOGIX

  • Fix to set item qualities to BAD on a failed CIP messages.

DF1_NGCTT

  • Added logic to ignore EOT from device during history collection.
  • Added max record properties to control history collection.
  • Added logic to prevent infinite loop if device returns the same history record repeatedly.

EAGLE

  • Fix to correctly assign calculation method.
  • Fix for GC Write sequence.
  • Fix for history record flow time units.
  • Added support to switch between Modbus and hex-ascii protocol.

FBNET

  • Fix to allow source and destination address values of two bytes in length.

FLOW AUTOMATION

  • Fix to prevent duplicate publishing of some event and alarm records.
  • Fix to correctly handle timestamp when additional bytes are in the response message.

MERCURY

  • Added option to publish raw volume in MCF.

MODBUS

  • Added option to null-terminate string writes.
  • Fixed bug that didn’t allow multiple string register writes to be combined.

MODBUS ENRON

  • Added support for unsolicited messages from AutoPILOT devices.

MODBUS OMNI

  • Added unit information to some history fields for correct translation in PGAS.

MODBUS SCADAPACK

  • Fix for retrieving DLOG records in logs found after the first disabled log.

ROC

  • Changed factor Fwv from Y to N to match AES output.
  • Fix for incorrect date/time values in Extended history.
  • Fix for using configured archive limits when collecting history.
  • Fixed TLP used for C6+ components during GC Write.

SCANCOM

  • Addition of ad hoc history requests.
  • Fixes to handle corrupt or out of sequence packets.
  • Fix for GC Write to multiple meter runs.
  • Change data log publishing so records are grouped together.

Publishing

PUBLISHER

  • Added commands to move and reset publisher.
  • Changed option terminology for including mapped fields or using ‘as-is’ data.

CSV

  • Added option to publish prove report records.
  • Added support for inSQL.

DATABASE

  • Added option to publish prove report records.
  • Added support for MySQL output.
  • Fixed bug that didn’t convert report record types to ascii.
  • FLOWCAL TRANSACTION QUEUE
  • Fix to prevent unnecessary snapshot records into table.

PGAS XML

  • Various fixes to unit translation and GC component encoding.

XML

  • Added ‘ad hoc’ xml node to history records.

Server

DATA SERVER

  • Added support for Alias objects.
  • Added port queue viewer (as a tab on all device and port windows).
  • Fix for losing browse information from an object if it was the source of a copy procedure.
  • Fix to allow adding OPC items to objects when another object, which doesn’t support items, exists and has the same name.
  • Fix for incomplete or slow results sent to OPC clients after a failed write.

Configuration

ACMCONFIG

  • New interface style.
  • Change so editing referenced objects is done in a tab view.
  • Fix for log viewer that could show messages out of order.
  • Change to log viewer filter so it uses all column data.
  • Fix for log viewer that would leave ‘paused’ mode when a down arrow key was pressed before reaching the end of the message list.
  • Disabled objects are now identified by their icon (this status is not yet sent remotely when changed by a different user).
  • Change to allow modifying the order of property objects (such as fields in a configurable archive object).
  • Update to configuration forms which breaks compatibility with older forms. Cannot mix forms from older ACM builds with forms from this and future ACM builds.

Database

WARNING:

 This installation requires a change to the existing database.

SQL SCRIPTS

  • Added SQL update 21 which contains new stored procedures for moving a publisher position.

System

SCANCOM MANUAL REQUEST Service

  • Fixed bug that could try to operate on a record when the record count was zero.

AUTOSOL Support Options

Pre-Sales Support

AUTOSOL representatives are standing by to answer your product and pricing questions. Let our team of experts assist you today to streamline your data collection and delivery tomorrow.

Contact Us

Product Knowledge Base

Browse how-to articles and perform keyword searches to find an answer to your questions.

View

Technical Support

Our expert technicians are available to help you troubleshoot a problem. Contact us at 281.286.6017 or submit a ticket.

Submit a Ticket