Version 7.1

Build 231        2016/01/19

WARNING:

 This installation requires a change to the existing database.

Connections

ALL CONNECTIONS

  • Made the Description property available as a read-only OPC item.

TCPIP

  • Added command to make a port report its status to the log viewer (for diagnostic purposes).
  • Fixed problem that didn’t allow the ‘Restore Defaults’ command to work properly.

TCPPOOL

  • Fixed problem that didn’t allow the ‘Restore Defaults’ command to work properly.

UDPBSAP

  • Fix to clear the ‘poll message pending’ flag when a connection is lost or aborted.

Protocols

ALL PROTOCOLS

  • Made the Description property available as a read-only OPC item.
  • Fixed problem that could make the Demand OPC item update before all poll tries were completed.

BENCHMARK

  • Fix for problem that didn’t properly handle multiple write data index.
  • Fix for problem that didn’t correctly invert digital values if configured to do so.
  • Fix to set bad quality on items that receive a NAK.

BSAP

  • Fix for problems related to poll cycle interruptions, delayed polling, and final Ethernet ACKs.
  • Fix to prevent demand polls from triggering history collection.
  • Fix to prevent history collection problem and writing to ‘#READ_BY_NAME’ OPC item.
  • Increase available meters to 32.
  • Fixes for internal implementation of commands.
  • Fix for problem that could cause ‘Verify writes’ option to fail.
  • Internal efficiency improvement with meter properties when collecting history.

CONTROLLOGIX

  • Fixes for tag name and structure member name lengths.
  • Fix for problem that caused interrupted poll errors after writing to an item.
  • Fix for ‘CIP Forward State’ that could sometimes cause a problem at the start of a poll.
  • Fix for problem related to ‘Verify writes’ option.

DF1 NGCTT

  • Removed the time-zone offset from history pointer adjustments.

EAGLE

  • Fix for problem that caused no retry attempts on Site ID request.

FBNET

  • Fix for problem that could cause history collection to stop after firmware version request.

FLOWAUTOMATION

  • Fix for problem that caused a Modbus error message to be treated as a time-out.
  • Fix for problem that did not correctly identify “Fwv” for CFX outputs.

GESRTP

  • Change to logic to ignore ‘reserved’ bytes in response header.

KIMRAY

  • Fix for problem that didn’t collect history from all of the meters in a device if events were available from some meters.

MERCURY

  • Fix for problem with data identification on the start and end index values of an audit record.

MODBUS

  • Fix for problem that could cause a memory leak when meter configuration requests timed-out.
  • Fix for problem that caused a right-click Demand request to fail.
  • Fix for problem that made a configured poll block fail until it was re-saved.

MODBUS ALIEN2

  • Initial release.

MODBUS ENRON

  • Fix for problem that didn’t combine write to registers into a single message (if possible).
  • Fix for problem that prevented GC records from being merged with volume records.
  • Add feature to support Daniel Chromatograph history retrieval.
  • Fix for problem that prevented meter configuration polls to be sent on their configured interval.
  • Add ability to collect history from record index ‘0’ if a device uses that position in its archive.
  • Fix for problem that didn’t properly calculate the collection index when it was moved by command and the move
    caused the index to wrap around the start or end of the buffer.

MODBUS KINDER MORGAN

  • Fix for problems related to sequence number wrapping and sequence number move/skip commands with chromatograph devices.
  • Fix for problem that prevented meter configuration polls to be sent on their configured interval.

MODBUS LUFKIN SAM

  • Change to data type of specific card data values so they can hold negative values.

MODBUS OMNI

  • Change to logic for assigning the meter calculation method (for liquid k-factor meters).

MODBUS SCADAPACK

  • Add support for V-Cone configuration
    read/write commands.

MODBUS SCANNER 1150

  • Change to logic to convert EFM analysis data to mole percentage values.

ROC

  • Change to the way the timestamp for history points is determined.
  • Support MarkWest history retrieval configuration.

SCANCOM

  • Fix to prevent mixing of ad-hoc meter items with other items.
  • Add feature to allow a configurable priority for ad-hoc history requests.
  • Fix for problem in the formatting of retry messages that could result in response processing to fail.
  • Fix memory leak that occurs during history collection.

TOTALFLOW

  • Fix a problem that could use ‘fixed’ instead of ‘live’ analysis values in the published meter configuration data.
  • Add properties to allow more granular configuration of block and packet sizes.
  • Correct some alarm translation values.

Publishing

PUBLISHER

  • Fix for potential error using global temporary database with filters.
  • Fix for a memory leak.
  • Additions for liquid product records.
  • Change to precision of float-to-double conversion from 7 digits to 8 digits.

CSV

  • Add feature to select output unit for flowing time field.
  • Add logic to include time portion of timestamp with midnight time values.
  • Add new token ‘$$FieldName$$ so output can be split into files for each field in a record.

CFX

  • Add ‘inferred volume’ calculation method for CFX format 7 and 8 files, to support liquid Coriolis meters.

DATABASE

  • Add feature to select output unit for flowing time field.
  • Add feature to dynamically create column names that include spaces.

AUTOSOL EFM DATABASE

  • Fix for problem that prevented inserts into a case-sensitive database.
  • FLOWCAL TRANSACTION QUEUE
  • Add ability to insert GC analysis records.

Server

DATA SERVER

  • Fix problem that prevented sending an OPC acknowledgment for the ‘reset stats’ item.
  • Add folder-level security features.
  • Fix to allow OPC item validation using an item’s alias text.
  • Fix for case-sensitive databases that could prevent old history deletion.

Configuration

ACMCONFIG

  • Update for UI component tools.
  • Fix for a problem with references to String objects during import and export.
  • Improve performance when deleting a large number of objects.
  • Fix for various memory leaks.
  • Add feature to select colors for log viewer and queue viewer.
  • Fix for various issues that caused problems when Disconnect and Connect were executed without stopping ACMConfig.
  • Add ability to specify the TCP port (used to connect to the log server) on the command line.
  • Fix bug that prevented copying objects when in ‘Primary Connection View’ mode.

Database

WARNING:

 This installation requires a change to the existing database.

SQL SCRIPTS

  • Add SqlUpdate_25 script file to add logic required for liquid product records.

    IMPORTANT:

     If you received a preliminary version of SqlUpdate_25.sql before this release, you must remove that file before updating to this release.

  • Add SqlUpdate_26 script file to correct problem with string objects that did not appear in referenced object lists.
  • Add SqlUpdate_27 script file to correct the data shown in the detail meter record report. Extends the size of the
    DataValue column in the table ‘tblItemStaging’.
  • Add new table and procedures to support liquid product records.

System

GC REQUEST MANAGER Service

  • Fix for case-sensitive databases.
  • LOG MESSAGE SERVER Service
  • Fix for a problem that could prevent log
    subscription changes.

AUTOSOL Support Options

Pre-Sales Support

AUTOSOL representatives are standing by to answer your product and pricing questions. Let our team of experts assist you today to streamline your data collection and delivery tomorrow.

Contact Us

Product Knowledge Base

Browse how-to articles and perform keyword searches to find an answer to your questions.

View

Technical Support

Our expert technicians are available to help you troubleshoot a problem. Contact us at 281.286.6017 or submit a ticket.

Submit a Ticket